AIO NextGen PTHP unit under a hotel window

AIO NextGen PTHP

AIO NextGen PTHP unit render

The NextGen PTHP fits standard PTAC wall sleeves.

The NextGen PTHP fits standard PTAC wall sleeves, making it a direct replacement for existing units and a practical choice for new construction. It keeps the familiar PTAC/PTHP design with updated engineering and controls. Compared to conventional PTACs, it offers a streamlined design, quieter operation, better air sealing, and high efficiency from a twin-rotary BLDC inverter compressor with integrated ERV.

User Experience

  • Quiet operation (27 dBA)
  • Compact, sleek, slim design
  • Durable all-metal paintable case
  • Option for washable filters or MERV 13 rated filters for room air
  • Accessible MERV 13 filters for outside-air
  • Auto-restart feature
  • Maintains uniform, consistent temperatures
  • Backed by a 10‑year limited warranty

Operations

  • Offers cooling, heating, dehumidification, and auto modes
  • Provides up to 50 CFM of fresh air
  • Selectable fan speeds: low, medium, high, and auto
  • Programmable outside-air intake
  • Includes a connection for bathroom exhaust
  • Efficient condensate disbursement system for cooling
  • Features sound and thermal barriers
  • Easy installation—compatible with any standard PTAC sleeve
  • Wide range of capacity in a single unit

Options

  • 1,800W electric heating capability staged as 900W + 900W
  • Features an optional condensate disbursement system for heating
  • Optional sleeve includes a ThermaSleeve insulator for enhanced insulation
  • AirSync technology for balanced airflow
  • Compatible with both 115V and 230V power sources
  • Offers hardwire or LCDI cord options
  • Choice of refrigerants: R-32

Efficiency

  • Features a twin-rotary BLDC inverter compressor
  • Integrated ERV for fresh air circulation
  • Utilizes Recovery+ technology, leveraging exhaust air to enhance condenser performance for heating and cooling
  • Equipped with high-performance independent ECM fans for outside-air supply and room air exhaust
  • Utilizes high-performance, extra-large C and V shaped heat exchangers
  • Incorporates a unique high-efficiency, highperformance backward ECM centrifugal condenser fan
  • Includes a high-performance ECM tangential fan for room supply-air
  • Designed with a sound and thermal barrier for enhanced comfort
  • Optional self-cleaning coils for minimal maintenance.

Controllers

  • Onboard touch controller dims after 15 seconds of inactivity

Optional Controllers

  • WiFi app for Android and iPhone
  • Wall Mounted Advanced touchscreen with a 7‑day program
  • Wall Mounted Basic touch controller
  • Third-Party thermostat interface
  • BACnet/Modbus interface
  • Central control system
Nextac
PTAC
PTHP
ComfortComfort
Comfort: 5 out of 5 stars
Comfort: 3 out of 5 stars
Comfort: 3 out of 5 stars
Cooling EfficiencyCooling Efficiency
Cooling Efficiency: 5 out of 5 stars
Cooling Efficiency: 3 out of 5 stars
Cooling Efficiency: 3 out of 5 stars
Heating EfficiencyHeating Efficiency
Heating Efficiency: 5 out of 5 stars
Heating Efficiency: 1 out of 5 stars
Heating Efficiency: 3 out of 5 stars
Reduced InfiltrationInfiltration
Reduced Infiltration: 5 out of 5 stars
Reduced Infiltration: 1 out of 5 stars
Reduced Infiltration: 1 out of 5 stars
QuietQuiet
Quiet: 5 out of 5 stars
Quiet: 1 out of 5 stars
Quiet: 1 out of 5 stars
AestheticsAesthetics
Aesthetics: 5 out of 5 stars
Aesthetics: 1 out of 5 stars
Aesthetics: 1 out of 5 stars
Fresh AirFresh Air
Fresh Air: 5 out of 5 stars
Fresh Air: 1 out of 5 stars
Fresh Air: 1 out of 5 stars

Airflow

AIO NextGen PTHP brings comfort and fresh air together in one compact unit. The optional ERV brings in fresh, filtered air while removing stale air—all through the unit’s existing exterior vents.

AIO NextGen PTHP airflow diagram, front view — supply, return, fresh and stale air pathsAIO NextGen PTHP airflow diagram, rear view — condenser intake and exhaust paths
  • Outside air
  • Recirculate air
  • Fresh air intake
  • Stale air exhaust

Fresh air (for units with ERV)

The fresh air intake enters through the same louver as the condenser air intake, passes through the ERV, and exits through an opening to the right of the supply air grille.

Recirculated supply air

The supply air is released through a fixed top grille.

Stale air intake (for units with ERV)

The stale air intake enters through an opening to the right of the return air grille, passes through the ERV, and exits through the same louver as the condenser air exhaust.

Recirculated return air

The return air is drawn through the integrated return air grille and filter located at the bottom of the unit.

Condenser air intake

The condenser air intake connection is compatible with any of the approved or custom louvers, provided they meet the minimum requirements.

Condenser and stale air exhaust

The condenser air exhaust connection is compatible with any of the approved or custom louvers, provided they meet the minimum requirements.

What's Inside

AIO NextGen PTHP internal components diagram

Key Specifications

High Performance
Heat Pump Only95°F¹105°F²115°F³
Capacity
Maximum (kBtu/h)17.01514.0
Recommended (kBtu/h)*12.510.410.0
Rated (kBtu/h)11.511.511.5
Minimum (kBtu/h)4.54.04.0
Power Input
Maximum (kW)2.001.92.0
Recommended (kW)*0.971.061.16
Rated (kW)0.961.211.35
Minimum (kW)0.330.410.48
Efficiency
Maximum8.58.16.6
Recommended11.59.88.2
AHRI Rated EER2129.57.7
AHRI (310/380) EER212--
Energy Star EER2---
SEER2***16--
Moisture removal (Pts/h)2.42.93.4
1
95°F
ID: 80°F, W.B. 67°F;
OD: 95°F, W.B. 75°F
2
105°F
ID: 80°F, W.B. 67°F;
OD: 105°F, W.B. 75°F
3
115°F
ID: 80°F, W.B. 67°F;
OD: 115°F, W.B. 75°F

* This is the recommended capacity for sizing the unit to the space.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.

Heat Pump Only**47°F¹17°F²5°F³0°F⁴-5°F⁵
Capacity
Maximum (kBtu/h)15.513.010.09.08.5
Recommended (kBtu/h)*12.511.59.08.58.5
Rated (kBtu/h)11.511.56.56.56.5
Minimum (kBtu/h)4.03.02.72.42.0
Power Input
Maximum (kW)1.421.651.321.291.31
Recommended (kW)*1.041.281.241.231.31
Rated (kW)0.91.281.01.041.03
Minimum (kW)0.30.380.370.350.35
Efficiency
Maximum3.22.32.122
Recommended3.62.52.1222
Rated3.82.52.22.061.95
AHRI (310/380) COP23.8----
Energy Star-----
Minimum4.142.32.322
HSPF2***8----
1
47°F
ID: 70°F, W.B. 60°F;
OD: 47°F, W.B. 43°F
2
17°F
ID: 70°F, W.B. 60°F;
OD: 17°F, W.B. 13°F
3
5°F
ID: 70°F, W.B. 60°F;
OD: 5°F, W.B. 3°F
4
0°F
ID: 70°F, W.B. 60°F;
OD: 0°F
5
-5°F
ID: 70°F, W.B. 60°F;
OD: -5°F

* This is the recommended capacity for sizing the unit to the space.

** The tables show Heat Pump performance only. An electric heating element can be added to provide an additional output of 3,100 or 6,100 BTU/h.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.

High Efficiency
Heat Pump Only95°F¹105°F²115°F³
Capacity
Maximum (kBtu/h)15.013.011.5
Recommended (kBtu/h)*11.59.58.5
Energy Star (kBtu/h)8.58.58.5
Minimum (kBtu/h)4.54.04.0
Power Input
Maximum (kW)1.721.571.35
Recommended (kW)*0.960.940.97
Energy Star (kW)0.640.810.97
Minimum (kW)0.330.410.48
Efficiency
Maximum8.88.27.7
Recommended1210.18.4
AHRI Rated EER2---
AHRI (310/380) EER2---
Energy Star EER21310.58.4
SEER2***---
Moisture removal (Pts/h)1.92.42.9
1
95°F
ID: 80°F, W.B. 67°F;
OD: 95°F, W.B. 75°F
2
105°F
ID: 80°F, W.B. 67°F;
OD: 105°F, W.B. 75°F
3
115°F
ID: 80°F, W.B. 67°F;
OD: 115°F, W.B. 75°F

* This is the recommended capacity for sizing the unit to the space.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.

Heat Pump Only**47°F¹17°F²5°F³0°F⁴-5°F⁵
Capacity
Maximum (kBtu/h)12.511.09.09.08.5
Recommended (kBtu/h)*10.08.58.07.58.5
Energy Star (kBtu/h)8.58.56.56.56.5
Minimum (kBtu/h)4.03.02.72.42.0
Power Input
Maximum (kW)1.041.211.241.291.31
Recommended (kW)*0.70.871.191.121.31
Energy Star (kW)0.610.871.01.041.03
Minimum (kW)0.30.380.370.350.35
Efficiency
Maximum3.62.62.1222
Recommended3.92.72.152.041.9
Rated-----
AHRI (310/380) COP2-----
Energy Star42.72.22.061.95
Minimum4.142.32.322
HSPF2***9.2----
1
47°F
ID: 70°F, W.B. 60°F;
OD: 47°F, W.B. 43°F
2
17°F
ID: 70°F, W.B. 60°F;
OD: 17°F, W.B. 13°F
3
5°F
ID: 70°F, W.B. 60°F;
OD: 5°F, W.B. 3°F
4
0°F
ID: 70°F, W.B. 60°F;
OD: 0°F
5
-5°F
ID: 70°F, W.B. 60°F;
OD: -5°F

* This is the recommended capacity for sizing the unit to the space.

** The tables show Heat Pump performance only. An electric heating element can be added to provide an additional output of 3,100 or 6,100 BTU/h.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.

High Performance
Heat Pump Only35°C¹41°C²46°C³
Capacity
Maximum (kW)5.04.44.1
Recommended (kW)*3.73.12.9
Rated (kW)3.43.43.4
Minimum (kW)1.31.21.2
Power Input
Maximum (kW)2.001.92.0
Recommended (kW)*0.971.061.16
Rated (kW)0.961.211.35
Minimum (kW)0.330.410.48
Efficiency
Maximum8.58.16.6
Recommended11.59.88.2
AHRI Rated EER2129.57.7
AHRI (310/380) EER212--
Energy Star EER2---
SEER2***16--
Moisture removal (L/h)1.11.41.6
1
35°C
ID: 26.7°C, W.B. 19.4°C;
OD: 35°C, W.B. 23.9°C
2
41°C
ID: 26.7°C, W.B. 19.4°C;
OD: 40.6°C, W.B. 23.9°C
3
46°C
ID: 26.7°C, W.B. 19.4°C;
OD: 46.1°C, W.B. 23.9°C

* This is the recommended capacity for sizing the unit to the space.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.

Heat Pump Only**8°C¹-8°C²-15°C³-17°C⁴-20°C⁵
Capacity
Maximum (kW)4.53.82.92.62.5
Recommended (kW)*3.73.42.62.52.5
Rated (kW)3.43.41.91.91.91
Minimum (kW)1.20.90.80.70.6
Power Input
Maximum (kW)1.421.651.321.291.31
Recommended (kW)*1.041.281.241.231.31
Rated (kW)0.91.281.01.041.03
Minimum (kW)0.30.380.370.350.35
Efficiency
Maximum3.22.32.122
Recommended3.62.52.1222
Rated3.82.52.22.061.95
AHRI (310/380) COP23.8----
Energy Star-----
Minimum4.142.32.322
HSPF2***8----
1
8°C
ID: 21.1°C, W.B. 15.6°C;
OD: 8.3°C, W.B. 6.1°C
2
-8°C
ID: 21.1°C, W.B. 15.6°C;
OD: -8.3°C, W.B. -10.6°C
3
-15°C
ID: 21.1°C, W.B. 15.6°C;
OD: -15°C, W.B. -16.1°C
4
-17°C
ID: 21.1°C, W.B. 15.6°C;
OD: -17.8°C
5
-20°C
ID: 21.1°C, W.B. 15.6°C;
OD: -20.6°C

* This is the recommended capacity for sizing the unit to the space.

** The tables show Heat Pump performance only. An electric heating element can be added to provide an additional output of 0.9 or 1.8 kW.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.

High Efficiency
Heat Pump Only35°C¹41°C²46°C³
Capacity
Maximum (kW)4.43.83.4
Recommended (kW)*3.42.82.5
Energy Star (kW)2.52.52.5
Minimum (kW)1.31.21.2
Power Input
Maximum (kW)1.721.571.35
Recommended (kW)*0.960.940.97
Energy Star (kW)0.640.810.97
Minimum (kW)0.330.410.48
Efficiency
Maximum8.88.27.7
Recommended1210.18.4
AHRI Rated EER2---
AHRI (310/380) EER2---
Energy Star EER21310.58.4
SEER2***---
Moisture removal (L/h)0.91.41.4
1
35°C
ID: 26.7°C, W.B. 19.4°C;
OD: 35°C, W.B. 23.9°C
2
41°C
ID: 26.7°C, W.B. 19.4°C;
OD: 40.6°C, W.B. 23.9°C
3
46°C
ID: 26.7°C, W.B. 19.4°C;
OD: 46.1°C, W.B. 23.9°C

* This is the recommended capacity for sizing the unit to the space.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.

Heat Pump Only**8°C¹-8°C²-15°C³-17°C⁴-20°C⁵
Capacity
Maximum (kW)3.73.22.642.62.5
Recommended (kW)*2.92.52.342.22.5
Energy Star (kW)2.52.51.911.91.9
Minimum (kW)1.20.90.790.70.6
Power Input
Maximum (kW)1.041.211.241.291.31
Recommended (kW)*0.70.871.191.121.31
Energy Star (kW)0.610.871.01.041.03
Minimum (kW)0.30.380.370.350.35
Efficiency
Maximum3.62.62.1222
Recommended3.92.72.152.041.9
Rated-----
AHRI (310/380) COP2-----
Energy Star42.72.22.061.95
Minimum4.142.32.322
HSPF2***9.2----
1
8°C
ID: 21.1°C, W.B. 15.6°C;
OD: 8.3°C, W.B. 6.1°C
2
-8°C
ID: 21.1°C, W.B. 15.6°C;
OD: -8.3°C, W.B. -10.6°C
3
-15°C
ID: 21.1°C, W.B. 15.6°C;
OD: -15°C, W.B. -16.1°C
4
-17°C
ID: 21.1°C, W.B. 15.6°C;
OD: -17.8°C
5
-20°C
ID: 21.1°C, W.B. 15.6°C;
OD: -20.6°C

* This is the recommended capacity for sizing the unit to the space.

** The tables show Heat Pump performance only. An electric heating element can be added to provide an additional output of 0.9 or 1.8 kW.

***SEER2 does not apply to PTHP-type units and is shown solely to enable comparison with similar heat pump systems. Values are for reference and comparison purposes only.